EXT-3D                                        Download catalogue 

EXT-3D-SB/CL3X-2586 600V LF

Factory wiring ( Cable Chain ) ( Robot Arms )

UL AWM cUL AWM UL Listing RoHS


                                                                                                   
Heat resistance                                    ★                          
Oil resistance                                       ★★              
Noise resistance                                                          
Flame resistance                                   ★★                 
Torsion resistance                              ★★                    
Flexibility resistance                           ★★                     
Cable carrier                                     ★★★★          

Application

  • Appropriate wiring for multi-joint unit portion. (Twist test 20 million times or more.)
  • Appropriate for cable bare wiring for high-speed moving. (Cable Bear test 20 million times or more.)
  • CL3X tha is the listing standard is acquired and it correspomds to NFPA70, 79.
  • Sheilded Robot cable with UL and cUL at 300V,105°C. (Category : AVLV2, AVLV8, QPTZ)

    Feature

    • Extremely fine conductor use.
    • High bending elasticity and heat resistant TPE is used for insulation.
    • Oil and heat resistant PVC used for sheath.
    • Low friction material used for sheath.
    • Flame resisting : UL VW-1, cUL FT1.

      Construction figure

      Surface marking

      Identification

      Construction table

      • ※3, 4 core has the [Y/G] earth cable of an equal size.
      • ※The test of 2000V/5 minute besides the withstand voltage test on above mentioned UL standard and the CSA standard is applied.

      Allowable ampacity

      • The allowable ampacity of this catalog is a value at one in the air construction and the ambient temperature 30°C.
      • Allowable ampacity is calculated based on JCS0168.
        Allowable ampacity is calculated excluding grounding conductor.
      • Please multiply the following adjustment factors by the ambient temperature.
      • Note) Please refer to P.253 when you use this cable according to NFPA 70 or NFPA 79.

      ●Adjustment factors (at ambient temperature)

      Movement characteristic

      • *)1 It is C when overall diameter of the cable is 20mm or more, and D when overall diameter of the cable is 30mm or more.
      • *)2 When overall diameter of the cable is 20mm or less.
      • ※The longevity of the cable inside a cable bearing is dependent on the travel distance.
        Please consult our Sales Department when wiring a travel distance of 5m or greater.

      Oil resistance

      ※A~C in the table indicate the characteristics below.

      • A:There is no problem on practical use at all.
      • B:Deterioration slightly no problem almost on practical use.
      • C:It is sometimes deteriorated to some degree, and not possible to use it.

      Standard sales length

      100m
      (Sales by short length is available for large sizes. Please contact us which sizes are available.)



Write a review

Note: HTML is not translated!
    Bad           Good

Ask a question about this product







Can't read the image? click here to refresh

Related Products

Taiyo Cabletec  Corporation - EXT-3D/CL3X-2517 LF 300V

Taiyo Cabletec Corporation - EXT-3D/CL3X-2517 LF 300V

EXT-3D                          &nb..

Taiyo Cabletec  Corporation -EXT- 3D-SB/CL3X-2517 LF 300V

Taiyo Cabletec Corporation -EXT- 3D-SB/CL3X-2517 LF 300V

EXT-3D                          &nb..

Taiyo Cabletec  Corporation -EXT- 3D/CL3X-2586 LF 600V

Taiyo Cabletec Corporation -EXT- 3D/CL3X-2586 LF 600V

EXT-3D                          &nb..

Taiyo Cabletec  Corporation- EXT-PREM/CMX-2517 LF 300V

Taiyo Cabletec Corporation- EXT-PREM/CMX-2517 LF 300V

EXT-PREM                          &..

Taiyo Cabletec  Corporation- EXT-PREM-SB/CMX-2517 LF 300V

Taiyo Cabletec Corporation- EXT-PREM-SB/CMX-2517 LF 300V

EXT-PREM                          &..

Tags: EXT-3D